Due to the name of the amplifier, ie Instrumentation Amplifier has become ambiguous meaning. Not all amplifiers are used in applications on the tools used in instrumentation amplifiers, and does not mean that all of the instrumentation amplifier is only used in instrumentation applications. Instrumentation amplifiers are widely used in many applications, call it as motor control in data acquisition to the automotive field. Once the importance of the discussion of the instrumentation amplifier results in a specific discussion about what is called the instrumentation amplifier, how the principle works? Do the same with operational amplifiers, and how and where to use them.
Instrumentation amplifier is different from operational amplifier. An instrumentation amplifier is a closed-loop gain with different inputs and outputs that can be said to be a single output with different sources. Meaning instrumentation amplifier is an amplifier that has a single output where the output is from a different input. Mostly, the impedance of the input terminal 2 is stable and balanced and has a high price, in general, of 1000 Giga Ohm, or even more. Input bias current should be lower than about 1 nano nano amperes to 50 amperes. Because by using operational amplifier output impedance is very low, only nominally by 1 or 2 m-ohms, at low frequencies.
Unlike operational amplifier, where the closed-loop gain obtained from the instrumentation amplifier is calculated using an external resistor between the inverting input and terhubunga output. An instrumentation amplifier has internal feedback resistor of the circuit is isolated from the input terminal of the amplifier. Where all the entries that exist in instrumentation amplifiers from two different input types, reinforcement comes from internal amplifier or a component derived from internal or external amplifier resistor.
When a signal is received, the bridge resistor changes, resulting in instability in the resistor bridge. It has an impact on the change in voltage over the bridge. The output signal is connected to the input signal resulting in a change in voltage instrumentation amplifier circuit. Thus, a constant DC voltage in the circuit. And in general, this DC voltage equal to the input. Since the primary function of the DC voltage instrumentation amplifier reject, or from the voltage coming from the second input, when reinforcement occurs.
Very clearly different indeed, if the operational amplifier circuit is generally used in the same application with instrumentation amplifier. Simply put, both the signal voltage and DC voltage, noise, or other types of stress will be the same as the reinforcement. As a result, the signal will survive the DC offset voltage and resulting noise. Therefore, even the most good operational amplifier too much is not effective in strengthening the very small signals.